Conditions for Running the DTC
Condition 1
- Before the ECM can report DTC P0116 failed, DTC P0101 must run and pass.
- DTC P0112, P0113, P0117, P0118, P0119, or P2610 is not set.
- The engine run time of the previous ignition cycle was greater than 10 minutes.
- The calculated engine cool down of the previous test was greater than 50 °C (120 °F).
- The ignition was OFF for greater than 330 minutes after the previous engine shut down.
- The accumulated air mass of the previous ignition cycle was greater than 6,000 grams.
- DTC P0116 runs once an ignition cycle when the above conditions are met.
Condition 2
- Before the ECM can report DTC P0116 failed, DTC P0101 must run and pass.
- DTC P0112, P0113, P0117, P0118, or P0119 is not set.
- The ECT at the previous engine shut down is greater than 82 °C (180 °F).
- The block heater is not detected.
- DTC P0116 runs once an ignition cycle when the above conditions are met.