Circuit/System Verification

  1. Ignition ON, verify that no starter relay, theft deterrent, or automatic transmission DTCs are set that would cause the ECM to disable starting.
  2. Ignition ON, observe the scan tool BCM Current Power Mode parameter. Place ignition switch in the crank position, the parameter should display Crank Request.
  3. Transmission range selector in park, verify the scan tool ECM PNP Switch and TCM Tr Switch parameters display Park/Neutral.
  4. Transmission range selector in park or neutral, attempt to start the vehicle. The starter relay should click and the engine should begin cranking.