Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the liftgate release actuator.
- Test for less than 1 ohm between the ground circuit terminal 5 and ground.
- If greater than the specified value, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool Rear Closure Ajar Sw. parameter is Inactive.
- If not the specified parameter, test the signal circuit terminal 6 for a short to ground. If the circuit tests normal, replace the BCM.
- Install a 3A fused jumper wire between the signal circuit terminal 6 and ground. Verify the scan tool Rear Closure Ajar Sw. parameter is Active.
- If not the specified parameter, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal replace the BCM.
- If all circuits test normal, test or replace the liftgate release actuator.