Circuit/System Description
The power seat is controlled through the seat adjuster switch. Battery voltage is supplied at all times to the seat adjuster switch from the POWER SEAT 25A circuit breaker that is located in the I/P fuse block. When the seat adjuster switches are in an inactive state, the switch contacts are closed to the switch ground circuit.
All seat motors are reversible. For example, when the seat horizontal forward switch is pressed to move the entire seat forward, battery voltage is applied through the switch contacts and the seat horizontal motor forward control circuit to the motor. The motor is grounded through the horizontal motor rearward switch contacts and the horizontal motor rearward control circuit to the motor. The motor runs in order to drive the entire seat forward until the switch is released. Moving the entire seat rearward works similarly to moving the entire seat forward, except that battery positive voltage and ground are applied on opposite circuits causing the motor to run in the opposite direction. All seat motors are powered this way.