Circuit/System Verification
- Ignition ON, observe the scan tool Driver Door Lock Sw, Psgr Door Lock Sw, Driver Door Unlock Sw and Psgr Door Unlock Sw parameters while using the appropriate door lock switch. The parameter should change between Inactive and Active.
- If the parameter does not change between commanded states, refer to DOOR LOCK SWITCH MALFUNCTION .
- Command the door latches to LOCK and UNLOCK with the scan tool, the doors should LOCK and UNLOCK.
- If a door latch does not LOCK or UNLOCK, refer to DOOR LOCK MALFUNCTION .