Component Testing
- Ignition OFF, disconnect the harness connector at the TP sensor.
- Test for 1,160-1,175 ohms between the 5-volt reference terminal A and the low reference terminal B.
- If not within the specified range, replace the TP sensor.
- Sweep the TP sensor through the entire range while monitoring the resistance between the signal terminal C and the low reference terminal B. The resistance should vary between 1,530-630 ohms without any spikes or dropouts.
- If not within the specified range or is erratic, replace the TP sensor.
- Sweep the TP sensor through the entire range while applying 5 volts and ground to the applicable terminals. Test the voltage between the signal terminal C and the low reference terminal B. The voltage should vary between 4.3-0.6 volts without any spikes or dropouts.
- If not within the specified range or is erratic, replace the TP sensor.