Fail-Safe Table
When any of the following malfunctions (DTCs) is detected, HVAC control module enters fail-safe mode. However, when HVAC control module detects normal operation of A/C system, fail-safe mode is canceled.
NOTE:
- For LCD model, DTC No. with asterisk (*) mark in the following table can not be detected by HVAC control module.
- For DTC B1563, only LCD model can be detected by HVAC control module.
FAIL-SAFE OPERATION AND TROUBLE AREA REFERENCE
| DTC No. | Trouble Area | Fail-Safe Operation | |
|---|---|---|---|
| When malfunction is detected during ignition switch is ON | When ignition switch is turned ON after malfunction is already detected | ||
| B1502 * | Inside air temperature sensor and/or its circuit malfunction | HVAC control module controls actuators assuming that inside air temperature is 25°C (77°F). | |
| B1503 | Evaporator temperature sensor and/or its circuit malefaction | HVAC control module controls actuators assuming that amount of evaporator temperature is -6°C (21.2°F). | |
| B1504 | Sunload sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of sunlight is 0 W/m2. |
| B1511 | Temperature control actuator (position sensor) and/or its circuit malfunction | Temperature control actuator is operated to "MAX HOT" direction for specified time. After that, operation of temperature control is actuator is stopped. | |
| B1512 | Air flow control actuator (position sensor) and/or its circuit malfunction | Air flow control actuator is operated to "DEF" position direction for specified time. After that, operation of air flow control actuator is stopped. | |
| B1513 | Temperature control actuator and/or its circuit malfunction | Operation of temperature control actuator is stopped. | |
| B1514 | Air flow control actuator and/or its circuit malfunction | Operation of Air flow control actuator is stopped. | |
| B1520 * | Temperature selector malfunction | HVAC control module controls actuators assuming that setting of temperature selector is 25°C (77°F). | |
| B1521 * | Blower speed selector malfunction | HVAC control module controls actuators assuming that as follows.
|
|
| B1530 | Air intake control actuator (position sensor) and/or its circuit malfunction | Air intake control actuator is operated to "FRE" direction for specified time. After that, operation of air intake control actuator is stopped. | |
| B1531 | Air intake control actuator and/or its circuit malfunction | Operation of temperature control actuator is stopped. | |
| B1551 | Serial communication circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that as follows.
|
| B1552 * | |||
| B1553 | CAN communication circuit malfunction | ||
| B1556 | Camshaft position (CMP) sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of engine speed is 0 rpm. |
| B1557 | Vehicle speed sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of vehicle speed is 0 km/h (0 mph). |
| B1561 | Engine coolant temperature sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected for 1 minutes. After that, HVAC control module controls actuators assuming that amount of engine coolant temperature is 90°C (194°F). | HVAC control module controls actuators assuming that amount of engine coolant temperature is 30°C (86°F) for 1 minutes. After that, HVAC control module controls actuators assuming that amount of engine coolant temperature is 90°C (194°F). |
| B1562 | Outside air temperature sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of outside air temperature is 20°C (68°F). |
| B1563 | A/C refrigerant pressure mulfunetion | HVAC control module controls actuators assuming that amount of refrigerant pressure is 0 MPa. | |