IMT (Intake Manifold Tuning) Valve Inspection
- Connect special tool (A) to IMT valve (1).
Special Tool
- 09917-47011
- Apply vacuum to IMT valve (1) and verify that throttle (2) fully closes within the specified range. If IMT valve (1) fails this check, replace it.CAUTION: Do not apply above 88 kPa (0.88 kg/cm2 , 661 mm Hg, 880 mbar) of negative pressure. Damage may occur to IMT valve (1).
IMT valve operation pressure
1.3-34 kPa (0.01-0.34 kg/cm 2 , 9.8-255 mm Hg, 13-340 mbar)
- Let the throttle (2) close for 15 seconds with no vacuum application and inspect throttle travel. If throttle travel decreases, replace IMT valve (1).