Removal and Replacement
Starting Motor Dismounting and RemountingDismounting
1. Disconnect negative (-) cable at battery.
2. Dismounting generator referring to Generator Dismounting and Remounting.
3. Disconnect magnetic switch lead wire and battery cable from starting motor terminals.
4. Remove 2 starting motor mount bolts.
5. Remove starting motor.
Remounting
Reverse the dismounting procedure noting the following.
- Tighten starting motor mount bolt (1) and starting motor battery cable nut.
Tightening torque
Starting motor mount bolt (a): 55 N.m (5.5 kg.m, 40.0 lbf.ft)
Starting motor battery cable nut: 11 N.m (1.1 kg.m, 8.0 lbf.ft)