Installation Procedure
- Install the CMP sensor.CAUTION: Refer to FASTENER NOTICE .
- Install the CMP sensor bolt.
Tightening torque
Tighten the bolt to 10 N.m (89 lb in) .
- Connect the engine wiring harness electrical connector (2) to the bank 1 intake CMP sensor.
- Install the air cleaner assembly. Refer to INSTALLATION PROCEDURE .