Transmission Fluid Cooler Flushing and Flow Test: Clean-up
- Turn the main function switch to the IDLE position and allow the supply vessel pressure to dissipate.
- Turn the main power switch to the OFF position.
- Disconnect the supply and waste hoses and the 12-volt power source from the vehicle.NOTE: A small amount of water may drain from the bottom of the unit when the air supply is disconnected. This is a normal operation of the built-in water separator.
- Disconnect the air supply hose from J 45096.
- Dispose of the waste ATF in accordance with all applicable federal, state, and local requirements.
- Clean the residual DEXRON®III from the transmission oil cooler, using compressed air to blow out the transmission oil cooler.