Conditions for Setting the DTC
The following condition is met for 1 second, 5 occurrences.
Input speed - 4.657 times the output speed is greater than 300 RPM and Input speed - 2.301 times the output speed is less than 100 RPM.
The following condition is met for 1 second, 5 occurrences.
Input speed - 4.657 times the output speed is greater than 300 RPM and Input speed - 2.301 times the output speed is less than 100 RPM.