Removal Procedure

Fig 1: Disconnecting Engine Wiring Harness Electrical Connector From Bank 2 Intake (CMP) Actuator Solenoid Valve
G04841351Courtesy of SUZUKI OF AMERICA CORP.
  1. Remove the engine mount strut bracket. Refer to ENGINE MOUNT STRUT BRACKET REPLACEMENT - RIGHT SIDE .
  2. Disconnect the engine wiring harness electrical connector (2) from the bank 2 intake camshaft position (CMP) actuator solenoid valve.
    Fig 2: Identifying CMP Actuator Solenoid Valve & Bolt (1 Of 2)
    G04841352Courtesy of SUZUKI OF AMERICA CORP.
  3. Remove the CMP actuator solenoid valve bolt.
  4. Remove the CMP actuator solenoid valve.