Installation Procedure

Fig 1: Identifying CMP Actuator Solenoid Valve & Bolt (2 Of 2)
G04841353Courtesy of SUZUKI OF AMERICA CORP.
  1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
  2. Install the CMP actuator solenoid valve.
    CAUTION: Refer to FASTENER NOTICE .
  3. Install the CMP actuator solenoid valve bolt.

    Tightening torque 

    Tighten the bolt to 10 N.m (89 lb in)  .

    Fig 2: Connecting Engine Wiring Harness Electrical Connector To Bank 2 Intake CMP Actuator Solenoid Valve
    G04841354Courtesy of SUZUKI OF AMERICA CORP.
  4. Connect the engine wiring harness electrical connector (2) to the bank 2 intake CMP actuator solenoid valve.
  5. Install the engine mount strut bracket. Refer to INSTALLATION PROCEDURE .