Removal Procedure
- Drain the cooling system. Refer to DRAINING AND FILLING COOLING SYSTEM (LY7 GE 47716 FILL) and DRAINING AND FILLING COOLING SYSTEM (LY7 STATIC FILL) .
- Remove the drive belt. Refer to REMOVAL PROCEDURE .
- Use the EN 46104 in order to retain the water pump pulley.
- Remove the water pump pulley bolts.
- Remove the water pump pulley.
- Remove the water pump bolts.
- Remove the water pump.
- Remove and DISCARD the water pump seal.
- Carefully clean the water pump sealing surfaces.