Terminal Removal Procedure
- Locate the connector position assurance (CPA) on the top of the wire dress cover. Slide the CPA forward.
Courtesy of SUZUKI OF AMERICA CORP.
- Slide the lever lock forward while pressing down on the lever lock release tab.
Courtesy of SUZUKI OF AMERICA CORP.
- The lever should be in the full forward position.
Courtesy of SUZUKI OF AMERICA CORP.
- Disconnect the connector from the component.
Courtesy of SUZUKI OF AMERICA CORP.
- Remove the dress cover by using a flat bladed tool to release the dress cover locking tabs and lift up on the dress cover.
- Cut the tie wrap that holds the wires to the connector body.
Courtesy of SUZUKI OF AMERICA CORP.
- Use a small flat-blade tool to pry one side of the nose piece up to the pre-stage position. When the nose piece is in the pre-staged position, the nose piece will be raised above the connector body the length of the step in the nose piece.
Courtesy of SUZUKI OF AMERICA CORP.
- Use a small flat-blade tool to pry the other side of the piece to the pre-stage position. If the nose piece is higher than the first step in the nose piece, gently push down on the nose piece until it meets with resistance from the connector body, you should feel the nose piece click into position.
Courtesy of SUZUKI OF AMERICA CORP.
- Insert the J 38125-213 into the small terminal release hole on the nose piece and gently pull on the back of the wire.
- See the release tool cross reference in the Reference Guide of the J-38125 Terminal Repair Kit to ensure that the correct release tool is used.