Component Testing
- Ignition OFF, disconnect the IGN MAIN relay 31.
- Test for 70-150 ohms of resistance between terminals 85 and 86.
- If the resistance is not within the specified range, replace the relay.
- Test for infinite resistance between the following terminals:
- 30 and 86
- 30 and 87
- 30 and 85
- 85 and 87
- Test for less then 2 ohms of resistance between terminals 30 and 87A.
- If greater then the specified range, replace the relay.
- Install a 3-amp fused jumper wire between relay terminal 85 and 12 volts. Install a jumper wire between relay terminal 86 and ground. Measure for less than 2 ohms of resistance between terminals 30 and 87.
- If greater than 2 ohms, replace the relay.