Circuit / System Verification
- Ignition ON, observe the scan tool Ext Trunk / Liftglass Rel Sw parameter while pressing and releasing the liftgate switch. The reading should change between Active and Inactive.
- If the reading does not change between Active and Inactive, refer to LIFTGATE SWITCH MALFUNCTION .
- Observe the scan tool Trunk Release Solenoid Command parameter while pressing and releasing the liftgate switch. The reading should change between On and Off.
- If the reading does not change between On and Off, refer to LIFTGATE RELEASE MALFUNCTION .