Installation Procedure
- Install the new seal on the A/C pressure transducer.
- Install the A/C pressure transducer.
Tighten: Tighten the pressure transducer, using 2 wrenches, to 8 N.m (71 lb in).
- Install the electrical connector.
- Install the air cleaner housing bolts and the air filter housing assembly.
Tighten: Tighten the air cleaner housing assembly retaining bolts to 12 N.m (106 lb in).
NOTE:
Refer to Fastener Notice
.