Control Head Inoperative
Control Head Inoperative
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| 1 | Check the fuse F19. Is the fuse open? |
- | Go to Step 2 | Go to Step 3 |
| 2 | Repair any short circuit and replace the open fuses. Did you complete the repair? |
- | System OK | - |
| 3 |
|
11-14 V | Go to Step 4 | Go to Step 5 |
| 4 |
|
- | System OK | - |
| 5 | Measure the voltage between terminal B13 of the connector and ground. Does the resistance measure equal to the specified value? |
0 V | Go to Step 6 | Go to Step 7 |
| 6 |
|
- | System OK | - |
| 7 |
|
- | System OK | - |