Typical Scan Tool Data
ECT Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine operating in Closed Loop Parameter Normal Range: Varies with ambient temperature |
|||
| ECT Sensor Signal | 129°C (264°F), 0.0 Volts | -40°C (-40°F), 5.0 Volts | -40°C (-40°F), 5.0 Volts1 |
| Low Reference | - | -40°C (-40°F), 5.0 Volts | - |
| 1 Internal ECM damage may occur if the circuit is shorted to B+. | |||