Typical Scan Tool Data
TP Sensor 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The ignition is ON and the engine is OFF. Parameter Normal Range: TP Sensor 1 7-21% |
|||
| 5-Volt Reference | 0% | 0% | 30-40% |
| TP Sensor 1 Signal | 0% | 80-90% | 85-99% |
| Low Reference | - | 85-95% | - |
TP Sensor 2
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The ignition is ON and the engine is OFF. Parameter Normal Range: TP Sensor 2 7-21% |
|||
| 5-Volt Reference | 80-90% | 80-90% | 0% |
| TP Sensor 2 Signal | 80-90% | 80-90% | 0% |
| Low Reference | - | 0% | - |