LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2007 >> SX4 Base, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Automatic Transmission) >> Repair Instructions >> Pressure Control Solenoid Valve Inspection >> Operation Check >> Using regulated DC power supply
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Using regulated DC power supply

WARNING: This page is about a different variant/trim than selected.
  1. Connect pressure control solenoid valve (1) with regulated DC power supply (2) as shown in Fig 1.
  2. Turn regulated DC power supply switch ON and increase voltage of power supply keeping current within 1.0 A.
  3. Check for gradual movement of valve (3) in the direction of arrow "A" as voltage is increased.
  4. Check movement of valve (3) in the direction of arrow "B" as voltage is decreased.
  5. Turn power supply switch OFF.
    CAUTION: Do not pass current 1.0 A or more, or pressure control solenoid is burned out.
    Fig 1: Connecting Pressure Control Solenoid Valve With Regulated DC Power Supply
    G04847801Courtesy of SUZUKI OF AMERICA CORP.