Not using regulated DC power supply

WARNING: This page is about a different variant/trim than selected.
  1. Connect pressure control solenoid valve (1) to battery (2) setting the 8 - 10 W bulb (4) on the way as shown in Fig 1.
  2. Check for movement of valve (3) in the direction of arrow "A".
  3. Disconnect pressure control solenoid valve (1) from battery (2) and check movement of valve (3) in the direction of arrow "B".
    CAUTION: Set 8 - 10 W bulb on the way, or pressure control solenoid valve is burned out.
    Fig 1: Connecting Pressure Control Solenoid Valve To Battery
    G04847802Courtesy of SUZUKI OF AMERICA CORP.