Home >> Suzuki >> 2007 >> SX4 Base, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Automatic Transmission) >> General Description >> OBD System Description - Comprehensive Component Rationality Monitor >> Output Shaft Speed Sensor Rationality Monitor >> Enable Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Enable Conditions

WARNING: This page is about a different variant/trim than selected.
ENABLE CONDITIONS

Parameter Minimum Maximum
Battery voltage 9 V -
Engine speed 400 rpm -
Output shaft speed (calculated from input shaft speed) 300 rpm -
Shift position "D", "3", "2" or "L" range
Transmission range sensor Normal condition or not monitored
Input shaft speed sensor Normal condition or not monitored
Engine speed signal (U0100) Normal condition or not monitored
CAN communication (U0073) Normal condition or not monitored