LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2007 >> SX4 Base, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 70 (Air Conditioning System) >> Repair Instructions >> Discharging, Adding Oil, Evacuating, and Charging Procedures for A/C System >> Successful Transfer Complete
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Successful Transfer Complete

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2008 Suzuki Reno, 2008 Suzuki Forenza, 2007 Suzuki Reno, 2007 Suzuki Forenza, and 2006 Suzuki Reno. However, it is still accessible from the selected car via links, so may be relevant.
  1. Close the high-side valve on the unit's control panel. Both valves should be closed.
  2. Start the vehicle and the A/C system.
  3. Let the engine run until the readings on the high-side gauge and the low-side gauge stabilize.
  4. Compare the readings to the system specifications.
  5. Check the evaporator outlet temperature to ensure that the A/C system is operating within the system specifications.
  6. Keep the A/C running.
  7. Close the high-side coupler valve.
  8. Disconnect the high-side hose from the vehicle.
  9. Open the high-side and low-side valves on the control panel. The system will quickly draw in refrigerant from both hoses through the low-side hose.
  10. Close the low-side coupler valve.
  11. Disconnect the low-side hose from the vehicle.