  1. Install the oil cooler inlet pipe assembly and the bolts.

    Tighten: 

    Tighten the oil cooler inlet pipe bolts to 35 N.m (26 lb-ft).

    Fig 1: Identifying Oil Cooler Inlet Pipe Assembly Bolts
    G04717266Courtesy of SUZUKI OF AMERICA CORP.
  2. Install the oil cooler outlet pipe assembly and the bolts.

    Tighten: 

    Tighten the oil cooler outlet pipe bolts to 35 N.m (26 lb-ft).

  3. Refill the transaxle fluid. Refer to Transaxle Fluid Level Checking Procedure .
  4. Install the engine under cover. Refer to ENGINE UNDER COVERS REMOVAL AND INSTALLATION .
  5. Connect the negative battery cable.
    Fig 2: Identifying Oil Cooler Inlet Pipe Assembly Bolts
    G04717267Courtesy of SUZUKI OF AMERICA CORP.