DTC P0134 Oxygen Sensor 1 (O2S1) No Activity or Open: Troubleshooting
WARNING: This page is about a different car, the 2005 Suzuki Reno and 2005 Suzuki Forenza. However, it is still accessible from the selected car via links, so may be relevant.
TROUBLESHOOTING CHART
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 | Perform an On-Board Diagnostic (OBD II) System Check. Was the check performed? |
- | Go to Step 2 | Go to "ON-BOARD DIAGNOSTIC (OBD II) SYSTEM CHECK :" |
| 2 |
Does the scan tool indicate CLOSED LOOP? |
80°C(176°F) 1200 RPM | Go to Step 3 | Go to Step 4 |
| 3 |
Does the scan tool indicate CLOSED LOOP? |
- | Go to Step 12 | Go to Step 4 |
| 4 |
Does the scan tool indicate the O2S1 voltage within the specified value? |
400 - 500 mV | Go to Step 5 | Go to Step 8 |
| 5 | Check the O2S1 harness connector for malfunction or poor connection and repair as needed. Is the repair complete? |
- | Go to Step 12 | Go to Step 6 |
| 6 |
Is the voltage above the specified value? |
600 mV | Go to Step 7 | Go to Step 11 |
| 7 |
Is the voltage below the specified value? |
300 mV | Go to Step 9 | Go to Step 11 |
| 8 | Check the O2S1 low circuit for an open or short to ground between terminal 4 of the O2S1 and terminal M29 of the ECM and repair as needed. Is the repair complete? |
- | Go to Step 12 | Go to Step 10 |
| 9 | Check the O2S1 signal circuit for an open or short to ground between terminal 2 of the O2S1 and terminal M12 of the ECM and repair as needed. Is the repair complete? |
- | Go to Step 12 | Go to Step 10 |
| 10 |
Is the repair complete? |
- | Go to Step 12 | - |
| 11 | Replace the O2S1. Is the repair complete? |
- | Go to Step 12 | - |
| 12 |
Does the scan tool indicate that this diagnostic has run and passed? |
- | Go to Step 13 | Go to Step 2 |
| 13 | Check if any additional DTCs are set. Are any DTCs displayed that have not been diagnosed? |
- | Go to "APPLICABLE DTC TABLE " | System OK |