Enable Conditions

WARNING: This page is about a different car, the 2006 Suzuki Reno and 2006 Suzuki Forenza. However, it is still accessible from the selected car via links, so may be relevant.

Current BLM Cell Valid? = TRUE

OR BLM Option selected = FALSE

AND Engine Speed >= 1, 600 RPM

AND Engine Speed <= 4, 300 RPM

AND Airflow <= 9 g/s

AND Airflow >= 40 g/s

AND Run Time > 50 s

AND Coolant Temperature > 70 °C

AND Stoichiometric Air/Fuel Ratio Commanded? = TRUE

AND DFCO Exit with Rich Bias Fueling = FALSE

AND TORQ Fuel Reduction in effect = FALSE

AND Disabling Faults Present = FALSE

AND Enable Timer > 2 s