Heated Oxygen Sensor (Sensor-2) Removal And Installation: Removal

WARNING: This page is about a different car, the 2008 Suzuki Grand Vitara, 2007 Suzuki Grand Vitara, and 2006 Suzuki Grand Vitara. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: To avoid danger of being burned, do not touch exhaust system when system is hot. Oxygen sensor removal should be performed when system is cool.
  1. Disconnect negative cable from battery.
  2. Detach oxygen sensor connector from bracket and then disconnect connector from oxygen sensor.
  3. Remove oxygen sensor (1) from exhaust manifold (2).
    NOTE: Be careful not to expose it to excessive shock.
    Fig 1: Identifying A/F Sensor
    G04807274Courtesy of SUZUKI OF AMERICA CORP.