DIAGNOSIS PRESSURE - PRESSURE-TEMPERATURE RELATIONSHIP

Temperature °C (°F)(1) Pressure kPa (psi)(1) Temperature °C (°F)(1) Pressure kPa (psi)(1)
-8(17.6) 113.1 (16.4) 9 (48.2) 296.2 (43.0)
-7(19.4) 121.5(17.6) 10(50.0) 309.6 (44.9)
-6(21.2) 130.2(18.9) 15(59.0) 383.7 (55.7)
-5 (23.0) 139.1 (20.2) 20 (68.0) 467.7 (67.8)
-4 (24.8) 148.4(21.5) 25 (77.0) 567.5 (82.3)
-3 (26.6) 157.9(22.9) 30 (86.0) 667.8 (96.9)
-2 (28.4) 167.6 (24.3) 35 (95.0) 785.6(113.9)
-1 (30.2) 177.8(25.8) 40(104.0) 916.4(133.0)
0 (32.0) 188.2(27.3) 45(113.0) 1 062.2 (154.0)
1 (33.8) 198.8(28.8) 50 (122.0) 1 222.1 (177.2)
2 (35.6) 209.9 (30.4) 55(131.0) 1 398.2 (202.8)
3 (37.4) 221.2(32.1) 60 (140.0) 1 589.6 (230.5)
4 (39.2) 232.9 (33.8) 65 (149.0) 1 799.0 (260.9)
5(41.0) 245.0 (35.5) 70(158.0) 2 026.6 (293.9)
6 (42.8) 257.4 (37.3) 75(167.0) 2 272.2 (329.5)
7 (44.6) 269.8(39.1) 80(176.0) 2 544.0 (369.0)
8 (46.4) 282.9(41.0) - -
(1) All calculated values are rounded to one decimal place.

Evaporator Range:  From -7 to 7°C (19.4 to 44.6°F), the temperatures represent the gas temperatures inside the coil and not on the coil surfaces. Add 2 to 6°C (36 to 43°F) to the coil and air-off temperatures.

Condenser Range:  From 45 to 70°C (113 to 158°F), the temperatures are not ambient. Add 19 to 22°C (66 to 72°F) to the ambient temperatures for proper heat transfer. Then refer to the pressure chart.

Example:

32°C (90°F) Ambient temperature + 22°C (40°F) = 54°C(130°F)

Condenser temperature, which yields 1 379 kPa (200 psi), based on 50 km/h (31 mph) airflow.