  1. Disconnect the negative battery cable.
  2. Remove the glove box. Refer to GLOVE BOX REMOVAL .
  3. Remove the footwell upper cover. Refer to INSTRUMENT PANEL REMOVAL .
  4. Remove the blower motor cooling hose.
  5. Remove the motor and the seal from the heater/air distribution case by gently pulling the motor straight down and out.
  6. Remove the screws that secure the motor to the heater/air distributor case.
  7. Remove the motor, the seal and the shock mount pads from the heater/air distributor case by gently pulling the motor straight down and out.
    Fig 1: Identifying Motor, Screws, Seal And Shock Mount Pads