Pull-in coil open circuit test

Check for continuity across magnetic switch "S" terminal (1) and "M" terminal (2). If no continuity, coil is open and should be replaced.

Fig 1: Checking Continuity Across Magnetic Switch S Terminal (1) And M Terminal (2)
G04847081Courtesy of SUZUKI OF AMERICA CORP.