LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2007 >> SX4 Base, Standard >> Repair and Diagnosis >> Electrical >> Charging Systems >> Repair Instructions >> Generator Dismounting and Remounting >> Dismounting
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Dismounting and Remounting: Dismounting

  1. Disconnect negative (-) cable at battery.
  2. Remove water pump and generator drive belt referring to WATER PUMP AND GENERATOR DRIVE BELT REMOVAL AND INSTALLATION .
  3. Remove air cleaner case referring to AIR CLEANER ASSEMBLY REMOVAL AND INSTALLATION .
  4. Remove intake manifold referring to INTAKE MANIFOLD REMOVAL AND INSTALLATION .
  5. Remove P/S pump referring to HYDRAULIC TYPE .
  6. Remove generator cover (1).
  7. Disconnect "B" terminal wire (2) and coupler (3) from generator.
  8. Remove generator mounting bolt (4) and generator pivot bolt (5) from generator.
  9. Remove generator (6) from engine.
    Fig 1: Identifying Generator Cover, Mounting Bolt And Generator Pivot Bolt
    G04847114Courtesy of SUZUKI OF AMERICA CORP.