  1. Disconnect the negative battery cable.
  2. Recover the refrigerant. Refer to Discharging, Adding Oil, Evacuating, and Charging Procedures for A/C System .
  3. Remove the suction hose/liquid pipe block retaining nuts at the fire wall.
    Fig 1: Identifying Suction Hose/Liquid Pipe Block-To-Expansion Valve Retaining Nuts
    G04717785Courtesy of SUZUKI OF AMERICA CORP.
  4. Remove the expansion valve connector block retaining stud bolts.
  5. Remove the expansion valve.
  6. Discard the O-rings.
    Fig 2: Identifying Expansion Valve Connector Block Retaining Stud Bolts
    G04717786Courtesy of SUZUKI OF AMERICA CORP.