Enable Conditions

WARNING: This page is about a different car, the 2006 Suzuki Reno and 2006 Suzuki Forenza. However, it is still accessible from the selected car via links, so may be relevant.

Sensor cooled status flag = FALSE

AND Transient Conditions status flag = FALSE

AND Off-board device control = FALSE

AND Airflow ≥ 2 g/s

AND Engine stable conditions met = FALSE

AND Ignition Voltage ≥ 10 V

AND Sensor warm enough = FALSE

AND Fuel reduction active = FALSE

AND Disabling Faults Present = FALSE

AND Engine Run Time ≥ 60 s

AND Coolant Temperature ≥ 20 °C

AND DFCO active = FALSE