Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 240 (Engine Performance - Diagnostics - Introduction) >> General Description >> OBD System Description - Comprehensive Component (Engine Input) Monitor >> IAT Skewed >> Enable Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Enable Conditions

WARNING: This page is about a different car, the 2006 Suzuki Reno and 2006 Suzuki Forenza. However, it is still accessible from the selected car via links, so may be relevant.

Common Enable Conditions Criteria:

Startup Coolant Saved? = TRUE

AND Startup IAT Saved? = TRUE enum

AND Soak Time? 480 min.

AND Engine currently running? = Engine Run enum

AND Disabling faults present? = FALSE boolean

AND IAT stored previous trip? = TRUE boolean

Skewed Low Test:

IAT Skew Low Test Reporting Allowed? = TRUE boolean

AND Startup Coolant > -20 °C

AND Airflow > 15 g/s

AND Vehicle Speed > 40 kph

AND Skewed Low Delay Timer ≥ 120 sec.

AND Absolute (IAT - Startup IAT) ≤ 10 °C

Skewed High Test:

Skewed High Test reporting allowed? = TRUE

AND Airflow > 15 g/s

AND Vehicle Speed > 40 kph

AND Skewed High Delay Timer ≥ 120 sec.

AND Absolute (IAT - Startup IAT) ≤ 10 °C

AND IAT < See table below.

KtI ATD_T_Skw Hi Max IAT:

KTI ATD_T_SKW HI MAX IAT

-60 -10
-20 10
0 30
20 50
60 90