Yaw Rate/G Sensor Assembly Removal and Installation: Installation
Reference: YAW RATE/G SENSOR INSPECTION
- Before installing yaw rate/G sensor assembly (1), check installing condition as follows.
- Deformations around sensor installation area (2) (in sensor bracket).
- Foreign matters on mating surface between sensor and sensor bracket.
- Install yaw rate/G sensor assembly (1) to floor panel.
Tightening torque
Yaw rate/G sensor assembly bolt a: 6.5 N.m (0.65 kg-m, 5.0 lb-ft)
- Connect connector to yaw rate/G sensor assembly.
- Install console box, referring to CONSOLE BOX COMPONENTS .
- Connect negative (--) cable to battery.