WARNING: This page is about a different car, the 2007 Suzuki SX4. However, it is still accessible from the selected car via links, so may be relevant.

While connected as the figure with plunger out, disconnect negative lead from terminal "M".

Check that plunger and pinion remain out.

If plunger and pinion return inward, replace the magnetic switch.

Fig 1: Disconnecting Negative Lead From Terminal M
G04847072Courtesy of SUZUKI OF AMERICA CORP.