Resistance Check

WARNING: This page is about a different car, the 2007 Suzuki SX4. However, it is still accessible from the selected car via links, so may be relevant.

Check resistance between pressure control solenoid valve (1) terminals. If check result is not as specified, replace solenoid valve.

Pressure control solenoid valve resistance 

Standard: 3.3 - 3.7 Ω (at 20°C (68°F)) 

Fig 1: Checking Resistance Between Pressure Control Solenoid Valve Terminals
G04847800Courtesy of SUZUKI OF AMERICA CORP.