FAIL-SAFE TABLE
| DTC No. | Trouble Area | Fail-Safe Operation | |
|---|---|---|---|
| When ignition switch is turned ON after malfunction is already detected | When malfunction is detected during ignition switch is ON | ||
| B1502 | Inside air temperature sensor and/or its circuit malfunction | HVAC control module controls actuators assuming that inside air temperature is 25°C (77°F). | |
| B1503 | Evaporator temperature sensor and/or its circuit malefaction | HVAC control module controls actuators assuming that amount of evaporator temperature is -6°C (21.2°F). | |
| B1504 | Sunload sensor and/or its circuit malfunction | HVAC control module controls actuators assuming that amount of sunlight is 0 W/m2 . | |
| B1511 | Temperature control actuator (position sensor) and/or its circuit malfunction | Circuit open: Temperature control actuator fixed to "MAX HOT" position. Circuit short: Temperature control actuator fixed to "MAX COOL" position. |
|
| B1512 | Air flow control actuator (position sensor) and/or its circuit malfunction | Circuit open: Air flow control actuator fixed to "DEF" position. Circuit short: Air flow control actuator fixed to "VENT" position. |
|
| B1513 | Temperature control actuator and/or its circuit malfunction | Stop the operation of temperature control actuator. | |
| B1514 | Air flow control actuator and/or its circuit malfunction | Stop the operation of Air flow control actuator. | |
| B1520 | Temperature selector malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that setting of temperature selector is 25°C (77°F). |
| B1521 | Blower speed selector malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that as follows.
|
| B1530 | Air intake control actuator (position sensor) and/or its circuit malfunction | Circuit open: Air intake control actuator fixed to "FRE" position. Circuit short: Air intake control actuator fixed to "REC" position. |
|
| B1531 | Air intake control actuator and/or its circuit malfunction | Stop the operation of temperature control actuator. | |
| B1551 | Serial communication circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that as follows.
|
| B1552 | |||
| B1553 | CAN communication circuit malfunction | ||
| B1556 | Camshaft position (CMP) sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of engine speed is 0 RPM. |
| B1557 | Vehicle speed sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of vehicle speed is 0 km/h (0 mph). |
| B1561 | Engine coolant temperature sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of engine coolant temperature is 90°C (194°F). |
| B1562 | Outside air temperature sensor and/or its circuit malfunction | HVAC control module keeps condition just before malfunction is detected. | HVAC control module controls actuators assuming that amount of outside air temperature is 20°C (68°F). |