  1. Disconnect negative (-) cable at battery.
  2. Remove water pump and generator drive belt referring to WATER PUMP AND GENERATOR DRIVE BELT REMOVAL AND INSTALLATION .
  3. Remove air cleaner case referring to AIR CLEANER ASSEMBLY REMOVAL AND INSTALLATION .
  4. Remove intake manifold referring to INTAKE MANIFOLD REMOVAL AND INSTALLATION .
  5. Remove P/S pump referring to HYDRAULIC TYPE .
  6. Remove generator cover (1).
  7. Disconnect "B" terminal wire (2) and coupler (3) from generator.
  8. Remove generator mounting bolt (4) and generator pivot bolt (5) from generator.
  9. Remove generator (6) from engine.
    Fig 1: Identifying Generator Cover, Mounting Bolt And Generator Pivot Bolt