LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2007 >> Grand Vitara Base, RWD, Standard >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine General Information And Diagnosis >> Diagnostic Information And Procedures >> Inspection of ECM and Its Circuits >> Resistance Check
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Resistance Check

  1. Remove ECM from its bracket by referring to ENGINE CONTROL MODULE (ECM) REMOVAL AND INSTALLATION .
    CAUTION: Never touch terminals of ECM itself or connect voltmeter or ohmmeter (2).
  2. Connect special tool (A) to ECM connectors (1) securely.
    NOTE: Do not connect the other connector of special tool to ECM.
  3. Check resistance between each pair of terminals of special tool connectors as listed in the TERMINALS CIRCUIT TABLE .
    CAUTION:
    • Be sure to connect ohmmeter probe from wire harness side of coupler.
    • Be sure to turn OFF ignition switch for this check.
    • Resistance in the TERMINALS CIRCUIT TABLE  represents that measured when parts temperature is 20°C (68°F).
      Fig 1: Connecting DVOM To ECM Connectors
      G04824709Courtesy of SUZUKI OF AMERICA CORP.
TERMINALS CIRCUIT TABLE

Terminals Circuit Standard resistance Condition
E23-16 to E23-8 Main relay 160 - 240 Ω Battery disconnected and ignition switch turned ON
E23-24 to E23-8 Fuel pump relay 160 - 240 Ω -
E23-6 to E23-8 Throttle actuator control relay 160 - 240 Ω -
C37-15 to E23-2/3 Fuel injector No. 1 10 - 14 Ω -
C37-34 to E23-2/3 Fuel injector No. 2 10 - 14 Ω -
C37-14 to E23-2/3 Fuel injector No. 3 10 - 14 Ω -
C37-33 to E23-2/3 Fuel injector No. 4 10 - 14 Ω -
C37-13 to E23-2/3 Fuel injector No. 5 10 - 14 Ω -
C37-32 to E23-2/3 Fuel injector No. 6 10 - 14 Ω -
C37-12 to E23-2/3 EGR valve (stepping motor No. 1 coil) 20 - 24 Ω -
C37-31 to E23-2/3 EGR valve (stepping motor No. 2 coil) 20 - 24 Ω -
C37-11 to E23-2/3 EGR valve (stepping motor No. 3 coil) 20 - 24 Ω -
C37-30 to E23-2/3 EGR valve (stepping motor No. 4 coil) 20 - 24 Ω -
C37-10 to E23-2/3 EVAP canister purge valve 25 - 30 Ω -
C37-29 to E23-2/3 IMT vacuum solenoid valve 33 - 45 Ω -