Home >> Suzuki >> 2007 >> Grand Vitara Base, AWD, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 65 (Engine General Information & Diagnosis) >> General Description >> OBD System Description - Comprehensive Component Monitor (Engine Output) >> IAC System Monitor >> Enable conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Enable conditions

WARNING: This page is about a different car, the 2008 Suzuki Grand Vitara. However, it is still accessible from the selected car via links, so may be relevant.
ENABLE CONDITIONS CHART

Parameter Minimum Maximum
Engine coolant temp. 20 (68) °C (°F)  
Engine mode Running
Idle sw On  
Battery voltage 11 V  
Vehicle speed   1 mph
Intake air temp. -10 (14) °C (°F) 70 (158) °C (°F)
Barometric pressure 75 kPa  
Canister purge valve duty 0%
Time from engine start 10 sec.  
Target engine speed 500 r/min 1400 r/min
APP change during monitor   0.04 V
Fuel system status Closed loop
IAC system status Idle with closed loop