Thermostat Removal And Installation: Installation
Reference: THERMOSTAT INSPECTION
Reverse removal procedure for installation noting the following points.
- When positioning thermostat (1) and O-ring on thermostat case, be sure to position it so that air bleed valve (2) comes at match mark (3) and into the recession of thermostat case.
- Use new O-ring when installing.
- Refill cooling system referring to Step 7 to 17 of COOLING SYSTEM FLUSH AND REFILL .
- Verify that there is no coolant leakage at each connection.