DTC Troubleshooting

DTC TROUBLESHOOTING TABLE

Step Action YES NO
1 Was "Electronic Stability Program Check" performed?  Go to Step 2. Go to ELECTRONIC STABILITY PROGRAM CHECK .
DTC check for ESP® 
  1. Connect scan tool to DLC with ignition switch turned OFF.
  2. Turn ignition switch ON and check DTC for ESP®.

Are DTC C1037 and/or U1126 detected? 
Go to applicable DTC diagnosis flow for troubleshooting. Go to Step 3.
Check sensor calibration 
  1. Calibrate steering angle sensor by referring to SENSOR CALIBRATION .
  2. Clear all DTC(s) and check DTC for ESP®.

Is DTC C1024 still detected? 
Go to Step 4. Steering angle sensor calibration was incompleted.
Check steering angle sensor 
  1. Check steering angle sensor referring to STEERING ANGLE SENSOR ON-VEHICLE INSPECTION .

Is it good condition? 
Substitute a known-good ESP® hydraulic unit/control module assembly and check DTC. Replace steering angle sensor.