"4" Position Switch Circuit Monitor
OPERATION REFERENCE
| DTC | P1723 |
| Monitor execution | Continuous |
| Monitor duration | 10 seconds |
ENABLE CONDITIONS
| Parameter | Minimum | Maximum |
|---|---|---|
| Battery voltage | 9 V | - |
| Engine speed | 400 | - |
| CAN communication (U0073), (U0100) | Normal condition or not monitored | |
TYPICAL MALFUNCTION THRESHOLDS
| P1723 |
| Monitor voltage ≥ 4.19 V or < 0.91 V |