Dismounting and Remounting
Starting Motor Dismounting and RemountingDismounting
1. Disconnect negative (-) cable at battery.
2. Dismounting generator referring to Generator Dismounting and Remounting.
3. Disconnect magnetic switch lead wire and battery cable from starting motor terminals.
4. Remove 2 starting motor mount bolts.
5. Remove starting motor.
Remounting
Reverse the dismounting procedure noting the following.
- Tighten starting motor mount bolt (1) and starting motor battery cable nut.
Tightening torque
Starting motor mount bolt a: 55 Nm (5.5 kg-m, 40.0 lb-ft)
Starting motor battery cable nut: 11 Nm (1.1 kg-m, 8.0 lb-ft)