LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2007 >> Aerio Base, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater And Ventilation >> Diagnosis Information & Procedure >> Scan Tool Data >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Scan Tool Data: Notes

As the data values given in the following are standard values estimated on the basis of values obtained from the normally operation vehicles by using a scan tool, use them as reference values. Even when the vehicles are in good condition, there may be cases where the checked values do not fall within each specifies data range. Therefore, judgement as abnormal should not be made by checking with these data alone.

SCAN TOOL DATA

Scan Tool Data Condition Normal Condition / Reference Value
Refer to Scan Tool Data Definitions  TEMP CONT SWITCH Each reference value is relative to the position of temperature selector of HVAC control module. Max Cool, P1, P2 - P20, P21, Max Hot
Refer to Scan Tool Data Definitions  MODE CONT SWITCH Each reference value is relative to the position of air flow selector of HVAC control module. VENT, BI-LEVEL, FOOT, DEF-FOOT, DEF
Refer to Scan Tool Data Definitions  FAN CONT SWITCH Each reference value is relative to the position of blower speed selector of HVAC control module. OFF, 1st, 2nd - 7th, 8th
Refer to Scan Tool Data Definitions  FAN DESIRE VOLT Reference value is relative to the position of blower speed selector of HVAC control module. 0 - 15.5 V
Refer to Scan Tool Data Definitions  AIR MIX POS SENSOR Reference value is relative to the position of temperature selector of HVAC control module. about 1.0 V (Max Hot)
about 4.0 V (Max Cool)
Refer to Scan Tool Data Definitions  MODE POS SENSOR Reference value is relative to the position of airflow selector of HVAC control module. about 1.0 V (DEF)
about 4.0 V (VENT)
Refer to Scan Tool Data Definitions  BLOWER FAN LOAD Position of blower speed selector is 1st or 2nd position. OFF
Position of blower speed selector is more than 3rd position. ON
Refer to Scan Tool Data Definitions  AIR INTAKE MODE Fresh air (FRE) mode is activated. FRE
Recirculation air (REC) mode is activated. REC
Refer to Scan Tool Data Definitions  REC INDICATOR LAMP Recirculation air (REC) indicator lamp is lighted. ON
Recirculation air (REC) indicator lamp is not lighted. OFF
Refer to Scan Tool Data Definitions  FRE INDICATOR LAMP Fresh air (FRE) indicator lamp is lighted ON
Fresh air (FRE) indicator lamp is not lighted OFF
Refer to Scan Tool Data Definitions  REAR DEF INDICATOR LAMP Rear defogger indicator lamp is lighted ON
Rear defogger indicator lamp is not lighted OFF