LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2006 >> XL-7 Base, RWD, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater And Ventilation >> Repair Instructions >> Air Flow Control Actuator Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Air Flow Control Actuator Inspection

  1. Remove air flow control actuator referring to AIR FLOW CONTROL ACTUATOR REMOVAL AND INSTALLATION .
  2. Check resistance between terminals.

    Air flow control actuator resistance 

    Terminal "d" and "e" (DEF position): Approx. 250 - 350 Ω 

    Terminal "c" and "d" (DEF position): Approx. 2.6 kΩ 

    Terminal "d" and "e" (VENT position): Approx. 2.6 kΩ 

    Terminal "c" and "d" (VENT position): Approx. 250 - 350 Ω 

  3. Connect battery positive (+) terminal to terminal "b" and battery negative (-) terminal to terminal "a". Check if position of air flow control actuator changes VENT to DEF.
  4. Connect battery positive (+) terminal to terminal "a" and battery positive (-) terminal to terminal "b". Check if position of air flow control actuator changes DEF to VENT.

    If malfunction is found, replace air flow control actuator with new one.

    Fig 1: Identifying Air Flow Control Actuator Terminals
    G04723291Courtesy of SUZUKI OF AMERICA CORP.